RAH-210 Residual Chlorine Monitor & AnalyzerOur line of chlorine residual monitors includes Hydro Instruments’ ampermetric analyzer. The Series RAH-210 Analyzer determines residual chemical levels in the sample water. The measurement cell consists of large Copper and Gold electrodes in direct contact with the sample water. This reagent-free analyzer is continuous and does not rely on older “sample and hold” methods — thus it provides a much improved process control.Note: Food-grade vinegar can be used as the pH buffer reagent if the water pH varies. If pH is relatively constant and you are measuring free chlorine, no buffer solution is required. |
|
![]() |
Main Features: • Measures free, or total chlorine • Detects Chlorine Dioxide levels • Monitors Bromine and Iodine • pH and Temperature Compensation • Uses food grade vinegar for buffer solution • Optional PH probe compensation available • Continuous measurement meter • Standard PID controller set point residual • Continuous sensor cleaning mechanism • Adjustable measurement range • Alarm contact relay for signal loss • Two loop powered 4-20 mA inputs and one 4-20 mA outputMaintenance: A continuously driven cleaning system is employed to prevent a concentration of impurities on the surface of the electrodes which reduces the need for maintenance. |
» Specifications Sheet » Download Brochure » Analyzer Comparison Flowchart | |
Details: The Series RAH-210 Free Chlorine Analyzer is available with pH & Temperature compensation performed in software. For applications with consistent pH levels in the process water, the known pH value can be manually input for software compensated residual analysis. A gravity driven buffer feed system is also available to inject the required chemicals for measuring Total Chlorine, Chlorine Dioxide, Iodine and Bromine.Basic Specifications: ELECTRICAL MEASUREMENT |
|
![]() RPH-250 – Probe-Style Residual Chlorine AnalyzerThe Series RPH-250 Analyzer makes use of the Amperometric method to determine residual levels in the sample water. The measurement is continuous, not relying on sample and hold methods, thereby allowing for better process control. The Free and Total Chlorine probe offers easily replaceable membrane caps.Because Chlorine residual measurement probes are sensitive to pressure and flow fluctuations, the RPH-250 is provided with everything needed to supply a steady sample water pressure at a consistent flow rate. A plastic pressure regulating valve with an attached pressure gauge is included with each unit. An integrally designed flow control valve and graduated metering tube make setting and maintaining the sample flow a snap. |
|
![]() |
RPH-250 Features: • Amperometric probe-style residual analyzer (Free or Total Chlorine) • Transparent probe & inlet flow cells • Available range: 0-2, 0-5, or 0-10 PPM • Allows simple calibration & maintenance • Automatic pH compensation software included • pH probe can be included (optional) • Available with pH and Temperature compensation without the need for buffer chemicals for free chlorine • PRV, pressure gauge, sample control valve & meter tube provided • Cross-sensitive for: chlorine dioxide, ozone, iodine, bromine, bromamine, Di & Tri-chloramine • Includes complete PID control program |
» Specifications Sheet » Download Brochure » Analyzer Comparison Flowchart | |
Basic Specs:ELECTRICAL • Power Consumption: 16 VA • Power Requirements: 120VAC, 50/60 Hz or 240VAC, 50/60 Hz, single phase • Output Signal: (2) 4-20 mA • Relay Contact: 10 Amps @ 120 VAC or 24 VDC, resistive load, 5 Amps @ 240 VAC, resistive load MEASUREMENT |
|
![]() Different Forms of ChlorineFREE CHLORINE COMBINED CHLORINE TOTAL CHLORINE When chloramines are present in a municipal water supply, total chlorine will be higher than free chlorine. |